Iris Management Suite
Technical Guide V1.7C 4/11/07
26
9 Dialler communications link and poll status
reporting
On every poll, a dialler reports its communications interface status to the
Polling Engine and these are shown in the Status area of the IRIS Dialler
Configuration screen for the dialler, as shown below.
Each interface is monitored on the dialler as follows:
Interface Monitoring method
ISDN Checks that low level communication with the local
exchange (at Layer 2) is possible. Does not incur
any call costs.
PSTN Checks line voltage.
Ethernet Checks:
Ethernet is synchronised (i.e. connected).
And:
Polling over Ethernet is possible, i.e. end-end
connection with ARC is operational.
GSM Checks that GSM is registered with the local base
station.
Panel Checks that the connection is not open or short
circuit. Note – for this to operate correctly a sense
resistor must be fitted at the end of line, as
described in the dialler installation guide.
Pin Inputs Checks that each input is not open or short circuit.
Note – for this to operate correctly sense resistors
must be fitted at the end of each line, as described
in the dialler installation guide.
If the equivalent box in the Monitor section is ticked and the status changes,
then an appropriate trouble/restore message is sent to the ARC, coded as
described in “SIA Codes on ARC Serial Link” section below.